Work Procedure
- SHIPPING MODE CANCEL OPERATION
- Turn ignition switch OFF.
- Press in (turn on) the extended storage switch. Refer to How To Check .
- Turn ignition switch ON.
- Turn ignition switch OFF and wait at least 2 seconds.
NOTE: Pressing in the extended storage switch moves the mode from Shipping to Normal.GO TO 2.
- SHIPPING MODE CANCEL CHECK
- Turn ignition switch ON.
- Check that extended storage warning message is not displayed in combination meter or display.
Work End.