Work Procedure: Description
If any of the following operations are performed, the initialization is necessary for normal operation of the power window system.
- When control unit is replaced.
- Electric power supply to the power window switch or motor is interrupted by blown fuse or disconnection and connection of the negative battery terminal.
- Removal and installation of the regulator assembly.
- Power supply to the main power window and lock/unlock switch or power window motor is cut off by the removal
of battery terminal or if the battery fuse is blown.
- Disconnection and connection of main power window and lock/unlock switch harness connector.
- Removal and installation of the motor from regulator assembly.
- Operation of regulator assembly as an independent unit.
- Removal and installation of the door glass.
- Removal and installation of the door glass run.
The following specified operations can not be performed under the non-initialized condition.
- Auto-up operation
- Anti-pinch function
- STEP 1
- Disconnect battery minus terminal or main power window and door lock/unlock switch connector. Reconnect it after a minute or more.
- Turn ignition switch ON.
- Operate power window switch to fully open the window.
- Hold the window up switch UP until it completely closes. After the glass stops at fully closed position, keep pulling the switch for 4 seconds or more.
- Check that AUTO-UP function operates normally.
GO TO 2.
- STEP 2
Check anti-pinch function. Refer to Work Procedure .
Inspection End.