Encoder Circuit Check

  1. CHECK ENCODER OPERATION 
    1. Ignition switch ON.
    2. Check signal between power window and door lock/unlock switch RH connector and ground with an oscilloscope.

      (+)

      (-)

      Signal

      (Reference value)

      Power window and door lock/unlock switch RH

      Connector

      Terminal

      D105

      9

      Ground

      Refer to following signal

      10

      G08686851Courtesy of NISSAN NORTH AMERICA, INC.

    Is the inspection result normal?

    YES

    Check intermittent incident. Refer to Inspection .

    NO

    GO TO 2.

  2. CHECK FRONT POWER WINDOW MOTOR RH POWER SUPPLY 
    1. Ignition switch ON.
    2. Check voltage between front power window motor RH connector and ground.

      (+)

      (-)

      Voltage

      (Approx.)

      Front power window motor RH

      Connector

      Terminal

      D104

      2

      Ground

      10

    Is the inspection result normal?

    YES

    GO TO 4.

    NO

    GO TO 3.

  3. CHECK HARNESS CONTINUITY 1 
    1. Ignition switch OFF.
    2. Disconnect power window and door lock/unlock switch RH connector and front power window motor RH connector.
    3. Check continuity between power window and door lock/unlock switch RH connector and front power window motor RH connector.

      Power window and door lock/unlock switch RH

      Front power window motor RH

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      D105

      5

      D104

      2

      Yes

    4. Check continuity between power window and door lock/unlock switch RH connector and ground.

      Power window and door lock/unlock switch RH

      Ground

      Continuity

      Connector

      Terminal

      D105

      5

      No

    Is the inspection result normal?

    YES

    Replace power window and door lock/unlock switch RH. Refer to Removal and Installation . After that, refer to Work Procedure .

    NO

    Repair or replace harness or connectors.

  4. CHECK GROUND CIRCUIT 
    1. Ignition switch OFF.
    2. Disconnect front power window motor RH connector.
    3. Check continuity between front power window motor RH connector and ground.

      Front power window motor RH

      Ground

      Continuity

      Connector

      Terminal

      D104

      4

      Yes

    Is the inspection result normal?

    YES

    GO TO 6.

    NO

    GO TO 5.

  5. CHECK HARNESS CONTINUITY 2 
    1. Disconnect power window and door lock/unlock switch RH connector.
    2. Check continuity between power window and door lock/unlock switch RH connector and front power window motor RH connector.

      Power window and door lock/unlock switch RH

      Front power window motor RH

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      D105

      4

      D104

      4

      Yes

    Is the inspection result normal?

    YES

    Replace power window and door lock/unlock switch RH. Refer to Removal and Installation .

    NO

    Repair or replace the harness or connectors.

  6. CHECK HARNESS CONTINUITY 3 
    1. Disconnect power window and door lock/unlock switch RH connector.

      Power window and door lock/unlock switch RH

      Front power window motor RH

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      D105

      10

      D9

      6

      Yes

      9

      5

    2. Check continuity between power window and door lock/unlock switch RH connector and front power window motor RH connector.
    3. Check continuity between power window and door lock/unlock switch RH connector and ground.

      Power window and door lock/unlock switch RH

      Ground

      Continuity

      Connector

      Terminal

      D105

      10

      No

      9

    Is the inspection result normal?

    YES

    Replace front power window motor RH. After that, Refer to Work Procedure .

    NO

    Repair or replace harness or connectors.