Calibration Of DECEL G Sensor

CAUTION: To calibrate the decel G sensor, make sure to use CONSULT.

(Calibration cannot be done without CONSULT).

  1. ALIGN THE VEHICLE STATUS 

    Stop vehicle with front wheels in straight-ahead position.

    GO TO 2

  2. PERFORM CALIBRATION OF DECEL G SENSOR 

    SYMBOL CONSULT

    1. Select "DECEL G SEN CALIBRATION" in "Work support" mode of "ABS".
    2. Select "Start".
    3. After approximately 10 seconds, select "End".
      NOTE: After approximately 60 seconds, it ends automatically.
    4. Ignition switch OFF, then turn it ON again.
      CAUTION: Be sure to perform above operation.

    GO TO 3

  3. CHECK DATA MONITOR 

    SYMBOL CONSULT

    1. Run vehicle with front wheels in straight-ahead position, then stop.
    2. Select "Data Monitor". Then make sure "DECEL G SEN" is within +/- 0.08G.

    Is the inspection result normal?

    YES

    GO TO 4

    NO

    Perform calibration of decel G sensor again, GO TO 1

  4. ERASE THE SELF DIAGNOSTIC RESULT MEMORY 

    SYMBOL CONSULT

    Erase "Self Diagnostic Result" mode of "ABS" and "ENGINE".

    Are the memories erased?

    YES

    Inspection End

    NO

    Check the items indicated by the self-diagnosis.