Diagnosis Procedure
- CHECK COOLING FAN MODULE POWER SUPPLY-1
- Turn ignition switch OFF.
- Disconnect cooling fan module harness connector.
- Turn ignition switch ON.
- Check the voltage between cooling fan module harness connector and ground.
Cooling fan module
Ground
Voltage
Connector
Terminal
F67
2
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 2.
NO
GO TO 7.
- CHECK COOLING FAN MODULE POWER SUPPLY-2
- Check the voltage between cooling fan module harness connector and ground.
Cooling fan module
Ground
Voltage
Connector
Terminal
F63
6
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 3.
NO
GO TO 8.
- Check the voltage between cooling fan module harness connector and ground.
- CHECK COOLING FAN MODULE GROUND CIRCUIT
- Turn ignition switch OFF.
- Check the continuity between cooling fan module harness connector and ground.
Cooling fan module
Ground
Continuity
Connector
Terminal
F67
1
Ground
Existed
- Also check harness for short to power.
Is the inspection result normal?
YES
GO TO 4.
NO
Repair or replace error-detected parts.
- CHECK COOLING FAN CONTROL SIGNAL CIRCUIT
- Disconnect IPDM E/R harness connector.
- Check the continuity between IPDM E/R harness connector and cooling fan module harness connector.
IPDM E/R
Cooling fan module
Continuity
Connector
Terminal
Connector
Terminal
F98
106
F67
4
Existed
107
3
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 5.
NO
Repair or replace error-detected parts.
- CHECK COOLING FAN MODULE OUTPUT SIGNAL CIRCUIT
- Reconnect all harness connectors disconnected.
- Disconnect cooling fan module harness connectors.
- Turn ignition switch ON.
- Check the voltage between cooling fan module harness connector and ground.
Cooling fan module
Ground
Voltage
Connector
Terminal
F63
5
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 6.
NO
Replace cooling fan module.
- CHECK COOLING FAN MOTOR
Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 9.
NO
Replace cooling fan motor. Refer to Exploded View .
- CHECK FUSE
- Disconnect 10 A fuse (No. 73) from fuse and fusible link holder.
- Check 10 A fuse for blown.
Is the fuse blown (open)?
YES
Replace the fuse. [Check the power supply if fuse is blown (open) again.]
NO
Perform the trouble diagnosis for power supply circuit.
- CHECK FUSE
- Disconnect 50 A fuse (No. N) from fuse and fusible link holder.
- Check 50 A fuse for blown.
Is the fuse blown (open)?
YES
Replace the fuse. [Check the power supply if fuse is blown (open) again.]
NO
Perform the trouble diagnosis for power supply circuit.
- CHECK INTERMITTENT INCIDENT
Perform Intermittent Incident .
Is the inspection result normal?
YES
Replace IPDM E/R. Refer to Removal and Installation .
NO
Repair or replace error-detected parts.