Component Inspection
- CHECK ECO MODE SWITCH
- Check continuity between ECO mode switch connector terminals.
ECO mode switch Condition Continuity Terminal 6 - 8 ECO mode switch is depressed. Yes ECO mode switch is released. No
Is the inspection result normal?
YES>>
Inspection End.
NO>>
Replace ECO mode switch. Refer to Removal and Installation .
- Check continuity between ECO mode switch connector terminals.