Work Procedure
- SAVING EPS CONTROL UNIT DATA (VEHICLE SPECIFICATIONS)
CONSULT
- Ignition switch OFF.
- Ignition switch ON.
- Select "Re/programming, Configuration".
- Select "EPS/DAST 3".NOTE:
If "EPS/DAST 3" is not displayed and EPS control unit data cannot be saved on CONSULT, GO TO 3.
- Select "Programming".
- Save EPS control unit data on CONSULT according to the CONSULT display.
NOTE:Save necessary data stored in EPS control unit in CONSULT according to the following instructions:
>>
GO TO 2.
- REPLACE EPS CONTROL UNIT
-
- Ignition switch OFF and wait for 10 seconds.
- Replace EPS control unit. Refer to Removal and Installation .
>>
GO TO 3.
-
- WRITE EPS CONTROL UNIT DATA (VEHICLE SPECIFICATIONS)
CONSULT
- Select "Programming".
- Perform programming according to the CONSULT display.
NOTE:Write data saved in CONSULT into a new EPS control unit according to the following instructions:
>>
Inspection End.