Reference Value
TERMINAL LAYOUT
PHYSICAL VALUES
NOTE:
- Specification data are reference values and are measured between each terminals.
- Pulse signal is measured by CONSULT.
| Terminal No. | Description | Condition | Value (Approx.) | ||
|---|---|---|---|---|---|
| + | - | Signal name | Input/Output | ||
| 1 (R) | 14 (B) | VVEL actuator motor power supply (bank 2) | Input | [Ignition switch: ON] | BATTERY VOLTAGE (11 - 14V) |
| 2 (B) | 14 (B) | VVEL actuator motor (High lift) (bank 2) | Output | [Engine is running]
|
0 - 14 V |
[Engine is running]
|
0 - 14 V |
||||
| 3 (W) | 6 (R) | VVEL control shaft position sensor 1 (bank 1) | Input | [Engine is running]
|
0.25 - 1.40 V |
[Engine is running]
|
0.25 - 4.75 V | ||||
| 4 (R) | - | Sensor ground [VVEL control shaft position sensor 1 (bank 2) ] | - | - | - |
| 5 (B) | 4 (R) | VVEL control shaft position sensor 1 (bank 2) | Input | [Engine is running]
|
0.25 - 1.40 V |
[Engine is running]
|
0.25 - 4.75 V | ||||
| 6 (R) | - | Sensor ground [VVEL control shaft position sensor 1 (bank 1) ] | - | - | - |
| 7 (B) | 6 (R) | Sensor power supply [VVEL control shaft position sensor 1 (bank 1) ] | - | [Ignition switch: ON] | 5 V |
| 8 (W) | 14 (B) | Power supply for VVEL control module | - | [Ignition switch: ON] | BATTERY VOLTAGE (11 - 14 V) |
| 9 (W) | 4 (R) | Sensor power supply [VVEL position sensor 1 (bank 2) ] | - | [Ignition switch: ON] | 5 V |
| 11 (W) | - | ENG communication line | Input/Output | - | - |
| 12 (B) | 14 (B) | VVEL actuator motor (High lift) (bank 1) | Output | [Engine is running]
|
0 - 14 V |
[Engine is running]
|
0 - 14 V |
||||
| 13 (R) | 14 (B) | VVEL actuator motor power supply (bank 1) | Input | [Ignition switch: ON] | BATTERY VOLTAGE (11 - 14 V) |
| 14 (B) | - | VVEL control module ground | - | - | - |
| 15 (W) | 14 (B) | VVEL actuator motor (Low lift) (bank 2) | Output | [Engine is running]
|
0 - 14 V |
[Engine is running]
|
0 - 14 V |
||||
| 16 (L/G) | 19 (L) | VVEL control shaft position sensor 2 (bank 1) | Input | [Engine is running]
|
3.50 - 4.75 V |
[Engine is running]
|
0.25 - 4.75 V | ||||
| 17 (O) | - | Sensor ground [VVEL control shaft position sensor 2 (bank 2) ] | - | - | - |
| 18 (O/L) | 17 (O) | VVEL control shaft position sensor 2 (bank 2) | Input | [Engine is running]
|
3.50 - 4.75 V |
[Engine is running]
|
0.25 - 4.75 V | ||||
| 19 (L) | - | Sensor ground [VVEL control shaft position sensor 2 (bank 1) ] | - | - | - |
| 20 (W/G) | 19 (L) | Sensor power supply [VVEL control shaft position sensor 2 (bank 1) ] | - | [Ignition switch: ON] | 5 V |
| 21 (BR/W) | 14 (B) | VVEL actuator motor relay abort signal (ECM) | Input | [Engine is running]
|
0 V |
| 22 (L/G) | 17 (O) | Sensor power supply [VVEL control shaft position sensor 2 (bank 2) ] | - | [Ignition switch: ON] | 5 V |
| 23 (BR/Y) | 14 (B) | VVEL control motor relay | Output | [Ignition switch: OFF] | BATTERY VOLTAGE (11 - 14 V) |
| [Ignition switch: ON] | 0 - 1.0 V | ||||
| 24 (R/W) | - | ENG communication line | Input/Output | - | - |
| 25 (W) | 14 (B) | VVEL control motor (Low lift) (bank 1) | Output | [Engine is running]
|
0 - 14 V |
[Engine is running]
|
0 - 14 V |
||||