Trunk Lid Release Does Not Operate Properly From Transmitters
- Disconnect RKE module connector C1. Turn ignition switch to RUN position. Check for battery voltage at module connector C1 terminal "B" (Pink wire). If battery voltage is present, go to next step. If battery voltage is not present, check for open circuit or short to ground in Pink wire.
- Disconnect RKE module connector C2. Connect jumper wire between module connector C2 terminal "B" (Black wire) and voltage. If trunk lid release solenoid activates, go to next step. If trunk lid release solenoid does not activate, check Black wire for an open circuit.
- Put transmission in Park or Neutral. With RKE module connector C2 still disconnected, ensure continuity is present between terminal "G" (White/Black wire) and ground. If continuity is not present, check White/Black wire for an open circuit or short to voltage. If all checks are to specification, replace RKE module.