DTC B1339: Device Power No. 3 Circuit Open: Description
Battery feed circuit from INADV POWER BUS/RAP fuse to BCM provides power for interior lighting. Voltage on interior lighting feed circuit from BCM must be 9-16 volts. DTC B1339 will set and store into memory if BCM detects less than one volt for longer than 0.3 seconds in battery feed circuit.
Current DTC B1339 will clear when control module no longer detects fault. A history DTC B1339 will clear after 100 consecutive ignition cycles if condition for malfunction no longer exists. Scan tool can be used to clear DTC.