July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Ambient Sensor Testing

With sensor removed from socket, resistance should be between 255 and 335 ohms when ambient temperature is between 70° and 80°F. Do NOT apply meter test for more than 5 seconds and do NOT hold sensor in hand while testing.