Except Mirage 1.6L
Connect 6-volt DC source across terminals No. 1 and 2 of ISC motor connector. See Fig 1
or Fig 2
. Reverse leads of 6-volt source. If motor does not operate in both directions, replace ISC motor assembly.
Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.