Installation Procedure
IMPORTANT:
The embossed arrows on the MAF sensor indicate the proper air flow direction. The arrows must point toward the engine.
- Install the MAF sensor (2) into the air duct adaptor.
- Install the retaining clamps, aligning notches, tighten clamps to the specified torque.
Tighten: Tighten the retaining clamps to 2 N.m (17 lb in).
- Connect the MAF sensor (2) wiring harness connector.
- Connect the IAT sensor (3) wiring harness connector.