THERMO Time Switch

  1. With engine cold and air temperature below 68°F (20°C), disconnect electrical connector from cold start injector and connect test lamp to connector terminals. Disconnect electrical connector from No. 1 ignition coil terminal.
  2. Operate starter. Test lamp should glow brightly. After 11 seconds (maximum), test lamp should dim or go out. If not, replace thermo time switch.