October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Air Temperature Sensor
Disconnect airflow sensor plug. Connect ohmmeter to airflow sensor terminals 6 and 22. Compare ohmmeter readings to specifications chart.
AIR TEMPERATURE SENSOR I SPECIFICATIONS
| Temperature |
Ohms (+/- 10%) |
| 32°F (0°C) |
5000-6200 |
| 68°F (20°C) |
2200-2800 |
| 86°F (30°C) |
150-1900 |