LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Porsche >> 2000 >> Boxster Base, Automatic >> Repair and Diagnosis (Single Page) >> Body & Frame >> Door Locks >> Lights, Lamps, Switches Interior, Theft Protection - Diagnosis >> Control Module Function >> Alarm Triggering And Alarm Output
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Alarm Triggering And Alarm Output

The alarm functions can be triggered only in the primed state. A non-blocked alarm input triggers an alarm in the primed state with an active signal. The alarm-triggering input then remains blocked for further alarm triggering until it returns to the inactive state. Then, following an inactive period of 10 seconds, it is again included in the alarm evaluation, provided that it was inactive for the entire inactive period.

In a priming cycle, the inputs Passenger compartment monitor, External 1 trigger a maximum of three alarms.

The alarm output is via:

ALARM OUTPUT CONDITIONS

Horn Depending on the country coding.
Direction indicator lights
Interior lights

The alarm output with all associated actions is interrupted immediately in the event of deactivation.