Level Control System Calibration (GROUP 4, NO. 2/03)

Publication date: 2003-02-28
Reference number: GROUP 4, NO. 2/03

LEVEL CONTROL SYSTEM CALIBRATION

LEVEL CONTROL SYSTEM CALIBRATION

TECHNICAL SERVICE BULLETIN

Reference Number(s): GROUP 4, NO. 2/03, Date of Issue:  February 28, 2003
PORSCHE: Cayenne S/Cayenne Turbo, As of 2003 (3)
GROUP: 4 - Running Gear
PART IDENTIFIER: 4316

EQUIPMENT

Air suspension, incl. Porsche Active Suspension Management/PASM (I No. 1BK) (air suspension with level control and height adjustment)

CONCERNS

Level-control calibration with the Porsche System Tester 2 (PST2) after:

Communication interruption and program abort during calibration with the PST2.

INFORMATION

When the level control module is calibrated with the PST2 and the current software version 15.0, the message "Communication problem with the control module" is displayed after the last height (=HR) is entered and the ">>" key is pressed. Calibration can now be continued with the ">>" key or the "ESC" key.

Continue the process with the ">>" key.

  1. Re-establish the connection with the ">>" key. After the key is pressed, the calibration program aborts and the message "Abort; test step condition not met" appears on the PST2 display.
    1. 1.1  Press the ">>" key. The "Function selection" menu is then shown. It is now necessary to check whether fault code 1437 "Control position not learned" is stored in the level-control fault memory.
    2. 1.2  If fault code 1437 is present, calibration must be repeated.

      Information: In this case, the fault code will be automatically deleted after calibration.

    3. 1.3  If the fault code is not present, the newly entered data is stored in the control module and the calibration process is then complete.
  2. If, after a communication interruption, the "ESC" key (= Abort) is pressed instead of the ">>" key, the message "Abort; test step condition not met" also appears. The same specifications as listed under point 1 then apply to the next procedure. The procedure as stated under point 1 should always be followed.

This problem has been remedied in the next PST2 software version 16.0, which will be distributed approximately mid-March '03.

LITERATURE

Cayenne Technical Manual, Group 4: