Starter Motor

No Load and Load Tests
<saacc44002-004>
No Load Condition Minimum Cranking Voltage 12 Volts (V)
Amperage 70 at 3000 _Amperes At RPM (A @ rpm)
Loaded Condition Minimum Cranking Voltage 9 Volts (V)
Amperage 315 at 1700 _Amperes At RPM (A @ rpm)
Locked Stator Condition Minimum Cranking Voltage 4 Volts (V)
Amperage 650-750 at 0 _Amperes At RPM (A @ rpm)