Conditions for Running
Cold Start
- The barometric pressure (BARO) is more than 74 kPa.
- The startup engine coolant temperature (ECT) is between 4-30°C (39-86°F).
- The startup intake air temperature (IAT) is between 4-30°C (39-86°F).
- The difference between the startup IAT and the startup ECT is 8°C (14.4°F) or less.
- The battery voltage is between 9-18 volts.
- The fuel level is between 15-85 percent.
- The fuel level does not increase more than 9 percent during this drive cycle.
- The engine run time is at least 10 minutes.
- The vehicle has been driven at least 5 km (3.15 miles) this drive cycle.
- The estimated ambient temperature at the end of this drive cycle is between 2-32°C (36-89°F).
- The shutdown ECT is at least 70°C (158°F).
- The ignition is turned OFF for at least one hour after this drive cycle.