Removal Procedure
- The fuel tank must be drained with a suitable, commercially-available fuel removal unit and suction hose - follow safety regulations and national legislation. The fuel tank is fitted with a refill limit float valve. This is located on the filler neck in the fuel tank. To prevent damaging the refill limit float valve, a suitable suction hose must be used.
- In the presence of fuel vapors or escaping fuel - observe safety regulations and national legislation. Store drained fuel in a suitable, saleable container.
- Remove the fuel tank. Refer to Fuel Tank Replacement .
- Remove the fuel tank sensor (1).
- Release the 2 retainers (3).
- Carefully pull from guide upward.
- Disconnect the 2 wires.
- Depress the 2 snap-on tongue (arrows) of the cable connectors.
IMPORTANT: The wire connectors are to be pulled out carefully for disassembling of the connection wires.IMPORTANT: The cable connectors is to be depressed by a blunt rod-shaped article.
IMPORTANT:
IMPORTANT:
Do not pull on the shaft of fuel tank sensor.