Installation Procedure
- Install the knock sensor.
Tighten: Tighten the bolt to 20 N.m (15 lb ft).
- Install the wiring harness plug.
- Install the intake manifold support.
Tighten: Tighten the 2 bolts to 8 N.m (71 lb in).
- Install the wiring harness plug into the bracket.
- Connect the wiring harness plug for the catalytic converter control oxygen sensor.
- Lower the vehicle by its full height.
- Connect the battery.
Install the ground connection to the ground terminal.
Tighten: Tighten the nut to 5 N.m (44 lb in).
- For programming procedures, refer to Control Module References .
- Close the hood.
NOTE:
Refer to Fastener Notice
.