System Description
The BorgWarner™ dual-scroll turbocharger (TC) incorporates a wastegate that is controlled by a pressure differential, that is determined by the engine control module (ECM) by means of a PWM solenoid, in order to regulate the pressure ratio of the compressor. A charge air bypass valve is integrated within the unit, and is also controlled by the ECM by utilizing a remotely mounted solenoid to prevent compressor surging and damage from vibrations by opening during abrupt closed throttle conditions. When the bypass valve is commanded open during closed throttle deceleration conditions, the bypass valve allows the air to recirculate in the TC and maintain compressor speed. Within a calibrated range during the closed throttle event, or upon a wide open throttle command, the bypass valve will then close to optimize TC response.
The purpose of this diagnostic is to determine if the charge air bypass valve is stuck closed. The ECM will first verify the integrity of the following sensors. The ECM then compares the actual measured mass air flow (MAF) to a modeled airflow that is derived from these inputs:
- The throttle position (TP)
- The engine speed
- The boost pressure sensor
- The manifold absolute pressure (MAP) sensor