Knock Sensor: Inspection
- INSPECT KNOCK SENSOR
- Measure the resistance of the sensor.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHART
| Tester Connection |
Specified Condition |
| 1 (Ground) - 2 (Output) |
120 to 280 kΩ at 20°C (68°F) |
If the result is not as specified, replace the knock sensor.