Home >> Scion >> 2014 >> tC Automatic Trans >> Repair and Diagnosis >> Body & Frame >> Windows >> Power Window Control System (Diagnostic Codes & Symptom Tests) >> Power Window Control System >> Auto Up Operation does not Fully Close Power Window (Jam Protection Function is Activated) [01/2014 - ] >> Inspection Procedure
July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!

Inspection Procedure

NOTE:
  • When a power window regulator motor assembly LH is reinstalled or replaced, the power window control system must be initialized.
  • After any door glass or a door glass run has been replaced, the jam protection function may operate unexpectedly when the auto up function is used. In such cases, the auto up function can be reinitialized by repeating the following operations at least 5 times:
    1. Close the power window by fully pulling up the power window regulator master switch assembly and holding it in the auto up position.
    2. Open the power window by fully pushing down the power window regulator master switch assembly.

HINT: 

Since the power window control system has functions that use LIN communication, first confirm that there is no malfunction in the communication system by inspecting the LIN communication functions in accordance with the "How to Proceed with Troubleshooting" procedures. Then, conduct the following inspection procedure.