Exhaust Gas RECIRCULATION: Testing
- Looking through opening in EGR valve body, check that valve shaft moves when engine reaches 3000-3500 RPM under no-load condition.
- If shaft does not move as specified, remove valve and manually check valve movement. If valve appears okay, check vacuum lines for leaks.
- If valve is sticking or binding, clean or replace as necessary. Check EGR pipe and gas passages from clogging and leaks. See Fig 1. Clean or replace as necessary.