- Turn ignition off. Disconnect ABS hydraulic unit harness connector. Measure resistance between hydraulic unit terminals. See CHECKING SOLENOID VALVE CIRCUIT RESISTANCE table. See Fig 1
. Resistance should be about 5-7 ohms. If resistance is as specified, go to next step. If resistance is not as specified, replace hydraulic unit.
CHECKING SOLENOID VALVE CIRCUIT RESISTANCE
| DTC |
Terminals No. |
| 31 |
3 & 9 |
| 33 |
4 & 10 |
| 35 |
1 & 10 |
| 37 |
2 & 9 |
| 61 |
12 & 9 |
| 62 |
11 & 10 |
Courtesy of SUBARU OF AMERICA, INC.
- Measure resistance between ground and terminal at hydraulic unit. See CHECKING SOLENOID VALVE FOR SHORT table. See Fig 1
. Resistance should be infinite. If resistance is as specified, go to next step. If resistance is not as specified, replace hydraulic unit.
CHECKING SOLENOID VALVE FOR SHORT
| DTC |
Terminals No. |
| 31 |
3 |
| 33 |
4 |
| 35 |
1 |
| 37 |
2 |
| 61 |
12 |
| 62 |
11 |
- Disconnect ABS/TCS control unit connectors. Measure resistance between ground and terminal at ABS/TCS control unit harness connector. See CHECKING ABS/TCS CONTROL UNIT CIRCUITS table. If resistance is infinite, go to next step. If resistance is not infinite, repair wiring harness as necessary.
CHECKING ABS/TCS CONTROL UNIT CIRCUITS
| DTC |
Terminals No. |
| 31 |
2 |
| 33 |
2 |
| 35 |
4 |
| 37 |
7 |
| 61 |
5 |
| 62 |
6 |
- Reconnect hydraulic unit connector. Ensure ABS/TCS connectors are disconnected. Measure resistance between terminal No. 6 at ABS/TCS connector 16-pin connector and ABS/TCS control unit 6-pin and 8-pin connectors as specified. See CHECKING ABS/TCS CONTROL UNIT CIRCUITS
. See Figure
. If resistance is 5-7 ohms, replace ABS/TCS control unit. If resistance is not 5-7 ohms, repair wiring harness as necessary.