Dual Switch

Pressure Switch (Dual Switch)

INSPECTION




1. Connect the manifold gauge to the service valve on the high-pressure side.
2. Remove the pressure switch harness connector. Using a circuit tester, inspect the ON-OFF operation of the pressure switch.