GENERAL SPECIFICATION

Cooling system Electric fan + Forced engine coolant circulation system
Total engine coolant capacity l  (US qt, lmp qt) MT: approx. 7.3 (7.7, 6.4)
AT: approx. 7.2 (7.6, 6.3)
Water pump Type Centrifugal impeller type
Discharge performance I Discharge rate l  (US gal, lmp gal) / min 20 (5.3, 4.4)
Pump speed - Discharge pressure 760 rpm - 2.9 kPa (0.3 mAq)
Engine coolant temperature 80°C (176°F)
Discharge performance II Discharge rate l  (US gal, lmp gal) / min 100 (26.4, 22.0)
Pump speed - Discharge pressure 3,000 rpm - 49.0 kPa (5.0 mAq)
Engine coolant temperature 80°C (176°F)
Discharge performance III Discharge rate l  (US gal, lmp gal) / min 200 (52.8, 44.0)
Pump speed - Discharge pressure 6,000 rpm - 225.4 kPa (23.0 mAq)
Engine coolant temperature 80°C (176°F)
Impeller diameter mm (in) 76 (2.99)
Number of impeller vanes 8
Pump pulley diameter mm (in) 60 (2.36)
Clearance between impeller and case Standard mm (in) 0.5 - 1.5 (0.020 - 0.059)
Thermostat Type Wax pellet type
Starting temperature to open 76 - 80°C (169 - 176°F)
Fully opens 91°C (196°F)
Valve lift mm (in) 9.0 (0.354) or more
Valve bore mm (in) 35 (1.38)
Radiator fan Motor input Main fan W 120
Sub fan W 120
Fan diameter / Blade Main fan 320 mm (12.6 in)/5
Sub fan 320 mm (12.6 in)/7
Radiator Type Down flow
Core dimensions Width x Height x Thickness mm (in) 687.4 x 340 x 16 (27.06 x 13.39 x 0.63)
Pressure range in which cap valve is open Coolant filler tank side kPa (kg/cm2 , psi) Above: 108±15 (1.1±0.15, 16±2)
Below: -1.0 to -4.9
(-0.01 - -0.05, -0.1 - -0.7)
Radiator side kPa (kg/2 , psi) Above only: 137±14.7 (1.40±.0.15, 20±2.1)
Fins Corrugated fin type
Reservoir tank Capacity l  (US qt, lmp qt) 0.45 (0.48, 0.40)
GENERAL SPECIFICATION

Coolant Recommended materials Item number Alternative
Coolant SUBARU coolant 000016218 Phosphoric acid (non-amine) type
Water for dilution Distilled water - Soft water or tap water
Cooling system protective agent Cooling system conditioner SOA345001 None
ENGINE COOLANT TEMPERATURE SPECIFICATION

Vehicle speed A/C compressor load Engine coolant temperature
Increase: 94°C (201°F)
or less
Decrease: 91°C (196°F)
or less
Increase: 95 - 96°C (203 - 205°F)
Decrease: 92 - 94°C (198 -201°F)
Increase: 97°C (207°F)
or more
Decrease: 95°C (203°F)
or more
Radiator fan operation Radiator fan operation Radiator fan operation
During acceleration: 19 km/h (12MPH) or less
During deceleration: 10 km/h (6 MPH) or less
OFF OFF Low-Speed High-Speed
Low Low-Speed Low-Speed High-Speed
High High-Speed High-Speed High-Speed
During acceleration: 20 - 69 km/h (12 - 43MPH)
During deceleration: 11 - 64 km/h (7 - 40 MPH)
OFF OFF Low-Speed High-Speed
Low High-Speed High-Speed High-Speed
High High-Speed High-Speed High-Speed
During acceleration: 70 - 105 km/h (43 - 65 MPH)
During deceleration: 65 - 103 km/h (40 - 64 MPH)
OFF OFF Low-Speed High-Speed
Low High-Speed High-Speed High-Speed
High High-Speed High-Speed High-Speed
During acceleration: 106 km/h (66 MPH) or more
During deceleration: 104 km/h (65 MPH) or more
OFF OFF High-Speed High-Speed
Low High-Speed High-Speed High-Speed
High High-Speed High-Speed High-Speed