Initialization Procedure
NOTE:
- Initialize the records inside the module by performing all the following steps regardless the item order.
- Buzzer sounds once when keeping the switch operation for three seconds with each seat in lock* status.
- After the completion of all items for initialization process, the buzzer sounds three times when finishing the final operation and turning the switch from ON to OFF.
- Move the seat backward using slide switch, and keep the seat lock* status for three seconds or more.
- Move the seat downward using tilt switch, and keep the seat lock* status for three seconds or more.
- Move the seat downward using lifter switch, and keep the seat lock* status for three seconds or more.
- Move the seat backward using reclining switch, and keep the seat lock* status for three seconds or more.
* :Seat lock is the status that there is no pulse output from the encoder within the specified period of time although the switch is being operated.
NOTE: When the following conditions are met, the initializing operation is cancelled even though the procedure is carried out halfway.- Any operation interval between each initialization procedures from 1) to 4) exceeded 10 second.
- All operations throughout initialization procedure 1) to 4) was not performed.
- During initialization procedure, power supply was cut off, or the voltage to the memory module exceeded the range of operating voltage.