Trunk Opener Switch
- Disconnect the trunk opener button connector.
- Measure the resistance between trunk opener button terminals.
Preparation tool: Circuit tester
Terminal No. Inspection conditions Specification 4 - 2 Open Less than 1 Ω Close 1 MΩ or more - Replace the trunk opener button if the inspection result is not within the standard value.