Data Monitor/Active Test
WARNING: This page is about a different car, the 2018 Subaru BRZ. However, it is still accessible from the selected car via links, so may be relevant.
- Data monitor
- Use the SSM4 and follow the display to bring up the [Normal sampling] screen in order to inspect the computer data.CAUTION: Due to slight measurement differences and factors such as differences in the measurement environment or vehicle aged-related variation, the value of the data monitor/active test can be widely varied. It is difficult to obtain a precise standard value (determined value) for this. Therefore, there may be cases where a fault is present, even if it is within the reference value.
PART NAME DESCRIPTIONItem name Description/display range Normal value Remarks (Main inspection items during a malfunction) [Control module voltage] - Indicates the battery voltage.
- Display range: 0 to 65.535 V
11 to 14 V: During idling Reference value: - IG ON: 12.5 V
- While cranking: 9.834 V
- At idling speed (after being warmed up): 13.359 V
If the battery voltage 11 V or less, other systems may be affected.[Battery Current] - Indicates the battery current.
- Display range: -125 to 125 A
Changes depending on the alternator generation amount: After warming up, when driving When a malfunction occurs, it may be due to a problem with the IB voltage system or sensor power supply. [Battery Temperature] - Indicates the battery ambient temperature which is calculated from the output from the battery temperature sensor (battery current sensor ASSY).
- Display range: -40 to 6513.5°C
Changes depending on the actual temperature: After warming up, when driving When a malfunction occurs, it may be due to a problem with the THB voltage system or sensor power supply. [Alt Voltage - Non Active Test] - Indicates the requested voltage when forced driving of the regulator is not being carried out.
- Display range: 0 - 80 V
Changes depending on the battery fluid temperature, driving conditions (12.4 - 14.8 V): After engine is started When a malfunction occurs, it may be due to a problem with the charging control system. [Alt Voltage - Active Test] - Indicates the requested voltage when forced driving of the regulator is being carried out.
- Display range: 0 - 80 V
Value of the request instruction voltage when the active test [Alternator control] is carried out: After engine is started - Indicates the generation voltage during [Active Test].
- When a malfunction occurs, it may be due to a problem with the charging control system.
[ALT Duty] - Indicates the charging control signal.
- Display range: 0 to 255 %
Changes depending on the alternator generation amount: During charging control When a malfunction occurs, it may be due to a problem with the charging control system.
When a malfunction occurs, it may be due to a problem with the charging control system.[Alternator control mode] - Indicates the alternator generation control mode.
- Display range: 0 - 255 %
Changes depending on the alternator generation amount: During charging control - [Alternator Mechanical Error Status] Displayed when it is determined that there is a mechanical error on the alternator. 0 - [Alternator Electrical Output Error Status] Displayed when it is determined that there is an electrical error on the alternator. 0 [Alternator High Temperature Error Status] Displayed when it is determined that there is a high temperature error on the alternator. 0 - [Alternator Communication Error Status] Displayed when it is determined that there is a communication error on the alternator. 0 - [Regulator Temperature] Alternator regulator temperature 170°C or less - - Use the SSM4 and follow the display to bring up the [Normal sampling] screen in order to inspect the computer data.
- Active test
- Using SSM4, display the [Active Test] screen according to the screen and perform the system operation check.
PART NAME DESCRIPTIONItem Contents Restrictions [Alternator control] Increases or decreases the alternator generation request voltage.
Able to request within the range of 12.8 - 14.3 V.While engine running