AT Shift Lock Solenoid and "P" Range Switch: Installation

Install in the reverse order of removal.

NOTE:
  • Refer to "COMPONENT" for each tightening torque. < Refer to COMPONENT , General Description. >
  • When installing the plate guide COMPL, set the select lever to the "D" range (normal mode position), and be careful for the following points.
    • Insert protrusion (B) of the plate guide COMPL into the hole on the solenoid unit (A).
    • Insert link (D) of the shift lock release into link (C) of the solenoid unit.
      Fig 1: Inserting Link Of Shift Lock Release Into Link Of Solenoid Unit
      G08571455Courtesy of SUBARU OF AMERICA, INC.
  • Connect the switch and solenoid unit terminals to the connector.
    Fig 2: Connecting Switch And Solenoid Unit Terminals To Connector
    G08571478Courtesy of SUBARU OF AMERICA, INC.