Execution Condition
| Secondary Parameters |
Execution condition |
| Time when ELCM switching valve is closed |
< 120000 ms |
| Purge control solenoid valve control duty |
> 0% |
| Precondition |
|
| Conditions to close the switching valve of ELCM intrusively. |
|
| Battery voltage |
≥ 10.9 V |
| Barometric pressure |
≥ 75.1 kPa (563 mmHg, 22.2 inHg) |
| Integrated value of calculated purge airflow since engine start |
≥ Value from Map |
| Atmospheric pressure - Intake manifold absolute pressure |
≥ 6.7 kPa (50 mmHg, 2 inHg) |
| ((Fuel system status |
= Fuel cut |
| for time) |
≥ ls |
| followed by |
|
| Fuel system status) |
Fuel cut |
| Ambient temperature |
≥ -25 °C (-13 °F) |
TEMPERATURE SPECIFICATION - MAP
| Ambient temperature °C (°F) |
0 (32) |
10 (50) |
20 (68) |
30 (86) |
40 (104) |
50 (122) |
| Integrated value of calculated purge airflow since engine start g (oz) |
72 (2.54) |
72 (2.54) |
72 (2.54) |
72 (2.54) |
72 (2.54) |
72 (2.54) |