October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Unit Inspection
- Push button start switch check
- Resistance check
- Measure the resistance between connector terminals.
STANDARD VALUE RESISTANCE SPECIFICATION
| Inspection terminals |
Inspection conditions |
Standard value |
| 5 (SSW1) - 6 (AGND) |
When the switch is not pressed |
10 k Ω or more |
| 1 (SSW2) - 6 (AGND) |
When the switch is not pressed |
10 k Ω or more |
| 5 (SSW1) - 6 (AGND) |
When the switch is pressed |
Less than 1 Ω |
| 1 (SSW2) - 6 (AGND) |
When the switch is pressed |
Less than 1 Ω |
NOTE:
If the resistance is not within the standard value, replace the push button start switch.
- LED illumination check
- Connect the battery positive and negative to the connector terminals and check the LED illumination condition.
TERMINAL DESCRIPTION - CRITERIA
| Terminal No. (Battery positive - battery negative) |
Criteria |
| 9 (SWIL) - 6 (GND) |
Character illumination lights up |
NOTE:
If the resistance is not within the standard value, replace the push button start switch.