October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Unit Inspection
- ST relay check
- Check the resistance between relay connector terminals.
Courtesy of SUBARU OF AMERICA, INC.
|
STANDARD VALUE RESISTANCE SPECIFICATION
| Inspection terminals |
Inspection conditions |
Standard value |
| 1 - 2 |
20°C |
93.8 to 136.4Ω |
| 3 - 5 |
When the battery voltage is not applied to the terminal 1 and terminal 2: |
10 k Ω or more |
| When the battery voltage is applied to the terminal 1 and terminal 2: |
Less than 1 Ω |
Courtesy of SUBARU OF AMERICA, INC.
|
- INHIBITOR relay check
- Check the resistance between relay connector terminals.
STANDARD VALUE RESISTANCE SPECIFICATION
| Inspection terminals |
Inspection conditions |
Standard value |
| 1 - 2 |
20°C |
93.8 to 136.4Ω |
| 3 - 5 |
When the battery voltage is not applied to the terminal 1 and terminal 2: |
10 k Ω or more |
| When the battery voltage is applied to the terminal 1 and terminal 2: |
Less than 1 Ω |
Courtesy of SUBARU OF AMERICA, INC.
|
- ST CUT relay check (with smart key system)
- Check the resistance between relay connector terminals.
STANDARD VALUE RESISTANCE SPECIFICATION
| Inspection terminals |
Inspection conditions |
Standard value |
| 1 - 2 |
20°C |
93.8 to 136.4Ω |
| 3 - 4 |
When the battery voltage is not applied to the terminal 1 and terminal 2: |
Less than 1 Ω |
| When the battery voltage is applied to the terminal 1 and terminal 2: |
10 k Ω or more |
| 3 - 5 |
When the battery voltage is not applied to the terminal 1 and terminal 2: |
10 k Ω or more |
| When the battery voltage is applied to the terminal 1 and terminal 2: |
Less than 1 Ω |
Courtesy of SUBARU OF AMERICA, INC.
|
- IGS relay check (with smart key system)
- Check the resistance between relay connector terminals.
STANDARD VALUE RESISTANCE SPECIFICATION
| Inspection terminals |
Inspection conditions |
Standard value |
| 1 - 2 |
20°C |
93.8 to 136.4Ω |
| 3 - 5 |
When the battery voltage is not applied to the terminal 1 and terminal 2: |
10 k Ω or more |
| When the battery voltage is applied to the terminal 1 and terminal 2: |
Less than 1 Ω |