Memory Height SW Does Not Function
- CHECK CENTER INFORMATION DISPLAY
.
Operate the memory height SW and check if the display for the memory height SW changes.
Does the display change?
Yes : The circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.No : Go to 2.
- CHECK DATA MONITOR
.
Using the Subaru Select Monitor, check the following items in the [Data Monitor] of [Power Rear Gate]. Refer to POWER REAR GATE (DIAGNOSTICS)>DATA MONITOR .
- Memory stop SW
Does the display switch between [OFF] ←→ [ON] according to memory height SW operation?
Yes : Input circuit is normal. Perform the inspection according to the diagnosis for cockpit control system. Refer to COCKPIT CONTROL (DIAGNOSTICS)>BASIC DIAGNOSTIC PROCEDURE>PROCEDURE .
No : Replace Power rear gate Control Module. Refer to POWER REAR GATE SYSTEM>POWER REAR GATE CONTROL MODULE .