IMT Valve Actuator Inspection
Reference: "IMT Valve Actuator Removal and Installation"
CAUTION:
Be sure not to apply battery voltage to IMT valve actuator for 10 seconds or more.
- Connect battery positive (+) and negative (-) terminals to IMT valve actuator (1) as shown in table below. If it does not operate as specified direction, replace IMT valve actuator.
DIAGNOSTIC INFORMATION AND PROCEDURES REFERENCE CHART
| Rotative direction |
a |
b |
| clockwise |
+ |
- |
| counterclockwise |
- |
+ |
Courtesy of SUZUKI OF AMERICA CORP.