September 30: LEMON manuals is back up on a temporary server! Slowness is possible
Airflow Meter Potentiometer
With ignition off, remove connector and check resistance between terminals. If resistance is not within specifications given in AIRFLOW METER SPECIFICATIONS table, replace airflow meter assembly.
AIRFLOW METER SPECIFICATIONS
| Application Terminal |
Resistance (Ohms) |
| Except Supra |
| E2-Vs |
20-400 |
| E2-Vc |
100-400 |
| E2-Vb |
| FX-16, MR2 & Van Only |
200-400 |
| E1-Fc |
Infinity at Close |
| Supra |
| Non-Turbo |
| E2-Vs |
20-600 |
| E2-Vc |
200-400 |
| E1-Fc |
Infinity at Close |
| Turbo |
| Vs-E1 |
Infinity |
| E1-Ks |
5000-10,000 |
| Vc-E1 |
10000-15,000 |
| E1-Vc |
5000-10,000 |