Description & Operation
This system controls the air/fuel mixture in response to warm up condition. The Vacuum Control Valve (VCV) and Vacuum Switching Valve (VSV) control air/fuel ratio. When valve is closed, a rich mixture is created. When valve is open, a lean mixture is created.