Using An Ammeter
- Disconnect the connector from the master switch.
- Connect the positive (+) lead from the ammeter to terminal No. 3 on the wire harness side connector, and the negative (-) lead to negative terminal of the battery. See Figure.
- Connect the positive (+) lead from the battery to terminal No. 4 on the wire harness side connector. See Figure.
- As the window goes down, and check that the current flows at approximately 7 amps.
- Check that the current increases approximately 14.5 amps or more when the window stops going down.
- If the operation is not as specified, replace the switch.