Ignition System: Distributor: Removal
- Record spark plug wire locations, and disconnect wires from distributor cap. Disconnect distributor electrical connector. Remove distributor cap and dust-proof packing ring. Set TDC by turning crankshaft until cylinder No. 1 is in compression stroke and timing mark aligns with TDC mark on timing case cover.
- Ensure distributor rotor points toward direction shown. See Figure. If rotor is not as shown, turn crankshaft pulley one complete revolution. Remove distributor hold-down bolts. Remove distributor. Remove "O" ring from distributor housing and discard.