EGR Vacuum Modulator: Turbo
- Disconnect vacuum hoses from EGR vacuum modulator. Plug one end of vacuum hose connection on EGR vacuum modulator.
- Apply air pressure through remaining port. Air should pass freely through air filter side of EGR vacuum modulator.