Bench Testing: Diodes
- With diode/rectifier assembly removed and on bench, contact positive diode plate terminal with one ohmmeter probe. Using other ohmmeter probe, contact each of 3 diode leads in same plate. Note ohmmeter reading. Reverse ohmmeter probes, and repeat tests for all diodes.
- All diodes should show continuity in one direction and no continuity in opposite direction. If any diode is defective, replace diode/rectifier assembly.