Circuit Description

The oxygen sensor monitors exhaust gas oxygen content and delivers an input signal to ECM. The ECM uses input signal to determine fuel injection system operation. Sensors include heater. Code is set when sensor does not output a rich condition once engine is at normal operating temperature, engine speed of 1500 RPM or more, and vehicle speed is at least 25 MPH for at least 2 minutes. Possible causes are:

NOTE: Oxygen sensor located nearest radiator is referred to as left oxygen sensor. See Fig 1.
Fig 1: Identifying Location Of Heated Oxygen Sensors
G00286277Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002