Circuit Description
The IAT sensor is a thermistor mounted in the Volume Airflow (VAF) meter to monitor air temperature flowing to intake manifold. Code is set when ECM detects a open or short circuit. Possible causes are:
- IAT sensor open or short circuit.
- IAT sensor malfunction.
- ECM malfunction.
NOTE:
If Codes 22, 24, 31 and 41 are output together, inspect ECM terminal E2 (ground) circuit. Repair as needed. See wiring diagram in the WIRING DIAGRAMS - 2.4L
article.