Circuit Description

The EGR system recirculates exhaust gas through intake system to reduce combustion temperature and NOx emissions. The amount of EGR valve opening is regulated by the EGR Vacuum Switching Valve (VSV), which is controlled by the ECM. Vacuum source to VSV is controlled by the Vacuum Control Valve (VCV). Amount of EGR valve opening is monitored by the EGR position sensor, which is mounted on EGR valve.

The EGR valve is closed (VSV on) under the following conditions:

Code is set when EGR cut-off, lift amount of EGR valve is .1" (2.6 mm) or more. Possible causes are: