Circuit Description
The EGR system recirculates exhaust gas through intake system to reduce combustion temperature and NOx emissions. The amount of EGR valve opening is regulated by the EGR vacuum modulator according to engine load. Vacuum source to valve is controlled by the Vacuum Switching Valve (VSV), which is controlled by ECM.
The EGR valve is closed (VSV on) under the following conditions:
- Engine is not warmed up.
- Vehicle under deceleration.
- Engine idling.
- High engine load.
- Engine speed more than 4400 RPM.
DTC is set when after engine is warmed up, intake manifold absolute pressure is more than calculated valve by ECM while EGR system is on. Possible causes are:
- EGR valve stuck closed.
- VSV open or short circuit.
- Manifold Absolute Pressure (MAP) sensor.
- EGR vacuum hose disconnected.
- ECM.