Throttle Position (TP) Sensor
AVALON TP SENSOR RESISTANCE SPECIFICATIONS
| Application Type |
Clearance In. (mm) |
Terminals Tested |
Ohmmeter Reading |
| 3.0L |
Fully Closed |
VTA & E2 |
200-6300 |
| " |
Fully Open |
VTA & E2 |
2000-10,200 |
| " |
" |
VC & E2 |
2500-5900 |
CAMRY TP SENSOR RESISTANCE SPECIFICATIONS
| Application Type |
Clearance In. (mm) |
Terminals Tested |
Ohmmeter Reading |
| 2.2L 4-Cyl. |
Fully Closed |
VTA & E2 |
200-5700 |
| " |
Fully Open |
VTA & E2 |
2000-10,200 |
| " |
" |
VC & E2 |
2500-5900 |
| 3.0L V6 |
Fully Closed |
VTA & E2 |
200-6300 |
| " |
Fully Open |
VTA & E2 |
2000-10,200 |
| " |
" |
VC & E2 |
2500-5900 |
CELICA TP SENSOR RESISTANCE SPECIFICATIONS
| Application Type |
Clearance In. (mm) |
Terminals Tested |
Ohmmeter Reading |
| 2.2L |
Fully Closed |
VTA & E2 |
200-5700 |
| " |
Fully Open |
VTA & E2 |
2000-10,200 |
| " |
" |
VC & E2 |
2500-5900 |
COROLLA TP SENSOR RESISTANCE SPECIFICATIONS
| Application Type |
Clearance In. (mm) |
Terminals Tested |
Ohmmeter Reading |
| 1.8L |
Fully Closed |
VTA & E2 |
200-5700 |
| " |
Fully Open |
VTA & E2 |
2000-10,200 |
| " |
" |
VC & E2 |
2500-5900 |
LAND CRUISER & LX470 TP SENSOR RESISTANCE SPECIFICATIONS
| Application Type |
Terminals Tested |
Ohmmeter Reading |
| 4.7L |
VC & E2 |
1250-2350 |
RAV4 TP SENSOR RESISTANCE SPECIFICATIONS
| Application Type |
Clearance In. (mm) |
Terminals Tested |
Ohmmeter Reading |
| 2.0L |
Fully Closed |
VTA & E2 |
200-5700 |
| " |
Fully Open |
VTA & E2 |
2000-10,200 |
| " |
" |
VC & E2 |
2500-5900 |
SIENNA TP SENSOR RESISTANCE SPECIFICATIONS
| Application Type |
Clearance In. (mm) |
Terminals Tested |
Ohmmeter Reading |
| 3.0L |
Fully Closed |
VTA & E2 |
200-6300 |
| " |
Fully Open |
VTA & E2 |
2000-10,200 |
| " |
" |
VC & E2 |
2500-5900 |
SUPRA NON-TURBO TP SENSOR RESISTANCE SPECIFICATIONS
| Application |
Terminals |
Ohmmeter Reading |
| 3.0L |
VC & E2 |
1200-3200 |
SUPRA TURBO MAIN TP SENSOR RESISTANCE SPECIFICATIONS
| Application Type |
Clearance In. (mm) |
Terminals Tested |
Ohmmeter Reading |
| 3.0L |
Fully Closed |
VTA & E2 |
340-6300 |
| " |
.027 (.69) |
IDL & E2 |
500 Or Less |
| " |
.032 (.81) |
IDL & E2 |
No Continuity |
| " |
Fully Open |
VTA & E2 |
2400-11,200 |
| " |
" |
VC & E2 |
3100-7200 |
SUPRA TURBO SUB-TP SENSOR RESISTANCE SPECIFICATIONS
| Application Type |
Clearance In. (mm) |
Terminals Tested |
Ohmmeter Reading |
| 3.0L |
Fully Closed |
VTA & E2 |
300-6300 |
| " |
.016 (.41) |
IDL & E2 |
500 Or Less |
| " |
.019 (.48) |
IDL & E2 |
No Continuity |
| " |
Fully Open |
VTA & E2 |
2000-10,800 |
| " |
" |
VC & E2 |
3500-6500 |
TACOMA TP SENSOR RESISTANCE SPECIFICATIONS
| Application Type |
Clearance In. (mm) |
Terminals Tested |
Ohmmeter Reading |
| 2.4L 4-Cyl. |
Fully Closed |
VTA & E2 |
200-5700 |
| " |
Fully Open |
VTA & E2 |
2000-10,200 |
| " |
" |
VC & E2 |
2500-5900 |
| 2.7L 4-Cyl. |
Fully Closed |
VTA & E2 |
200-5700 |
| " |
Fully Open |
VTA & E2 |
2000-10,200 |
| " |
" |
VC & E2 |
2500-5900 |
| 3.4L V6 |
Fully Closed |
VTA & E2 |
200-5700 |
| " |
Fully Open |
VTA & E2 |
2000-10,200 |
| " |
" |
VC & E2 |
2500-5900 |
TERCEL TP SENSOR RESISTANCE SPECIFICATIONS
| Application Type |
Clearance In. (mm) |
Terminals Tested |
Ohmmeter Reading |
| 1.5L |
Fully Closed |
VTA & E2 |
200-5700 |
| " |
Fully Open |
VTA & E2 |
2000-10,200 |
| " |
" |
VC & E2 |
2500-5900 |
T100 TP SENSOR RESISTANCE SPECIFICATIONS
| Application Type |
Clearance In. (mm) |
Terminals Tested |
Ohmmeter Reading |
| 2.7L 4-Cyl. |
Fully Closed |
VTA & E2 |
200-5700 |
| " |
Fully Open |
VTA & E2 |
2000-10,200 |
| " |
" |
VC & E2 |
2500-5900 |
| 3.4L V6 |
Fully Closed |
VTA & E2 |
200-5700 |
| " |
Fully Open |
VTA & E2 |
2000-10,200 |
| " |
" |
VC & E2 |
2500-5900 |
4RUNNER TP SENSOR RESISTANCE SPECIFICATIONS
| Application Type |
Clearance In. (mm) |
Terminals Tested |
Ohmmeter Reading |
| 2.7L 4-Cyl. |
Fully Closed |
VTA & E2 |
200-5700 |
| " |
Fully Open |
VTA & E2 |
2000-10,200 |
| " |
" |
VC & E2 |
2500-5900 |
| 3.4L V6 |
Fully Closed |
VTA & E2 |
280-6400 |
| " |
Fully Open |
VTA & E2 |
2000-11,600 |
| " |
" |
VC & E2 |
2700-7700 |