Circuit Description
ECM compares waveform of oxygen sensor located before catalytic converter with waveform of oxygen sensor located after converter to determine if converter performance has deteriorated. If both waveforms change at similar rate, catalyst performance has deteriorated. DTC is set when both oxygen sensors have same amplitude after vehicle is driven for 5 minutes at 20-50 MPH. Possible causes are:
- Defective catalytic converter.
- Oxygen sensor circuit is open or shorted.
- Defective oxygen sensor.