CHARGING SYSTEM SERVICE DATA (GENERATOR)

Application Specification
Rated Output 12 Volts/100 Amps
Rotor Coil resistance @ 68°F (20°C) 2.1-2.5 Ohms
Slip Ring Diameter
Standard 0.559-0.567 In. (14.2-14.4mm)
Minimum 0.504 In. (12.8mm)
Brush Exposed Length
Standard 0.413 In. (10.5mm)
Minimum 0.059 In. (1.5mm)
CHARGING SYSTEM SERVICE DATA (VOLTAGE REGULATOR)

Application Specification
Regulating Voltage 13.2-14.8 Volts